GE Fanuc PLC Supplier
A full line of automation and control products from top manufacturers
delivered where you want them, when you want them.
Home
About Us
Contact Us
   
  GE Fanuc Product's
Series 90-30
Series 90-70
PAC Systems Rx3i
PAC System Rx7i
Genius IO
Field Control PLC
Series One
Series Three
Series Five
Series Six
Versamax
Proficy Cimplicity Software
PLC Repair Pricing
PLC Surplus
GE PLC's Legacy
   
  GE Fanuc CNC Products
Series A03B
   
  GE Fanuc News
View GE Fanuc News
More about GE Fanuc
   
  Automation Products
ABB TRIO I/O
AC Tech Drives
Cognex Vision
Computer Dynamics
Control Techniques
Datalogic Scanning
DVT Cameras, Sensors
Emerson Drives & Motors
Eurotherm Drives
GE Fanuc CNC Parts
Horner Electric & OCS
IAI Intelligent Actuator
Lenze
Maple Systems
Saftronics/Fincor Drives
Siemens Drives
Total Control Products (TCP)
Xycom Industrial Computers
   
  Engineering Services
PLC Software Conversion
Machine Vision Systems
Machine Vision Software
   
  Remote Telemetry
Sentinel Remote Telemetry
Sentinel 1000/3000
Sentinel RM Water
Sentinel Plus Software
Home > News > April 28, 2006

Introducing the New VersaMax® Modular Modbus Master Module
Simple Interface Support to PAC Controllers

GE Fanuc's New VersaMax® Micro 64 Ethernet Module

New VersaMax Modular Genius NIU Modbus Master Module

Summary
The VersaMax Serial Communications Module, IC200CMM020, operates as a Modbus RTU Master in a VersaMax I/O Station controlled by a Genius Network Interface Unit. The serial Communications Module may be installed at any location in the I/O Station. Up to two Serial Communications modules can be used per I/O Station. This new module allows the user to easily connect to Modbus Slave devices remotely such as Variable Frequency Drives, Bar Code Readers, displays and much more.

Product Overview
Modbus RTU Communications
The VersaMax Serial Communications module supports Modbus RTU Master protocol. To operate as a Master, the Serial Communications module must receive commands from a remote host. For example, the remote host could be an RX7i PLC that communicates with the I/O Station’s VersaMax Genius NIU via a Genius Bus Controller module.

Commands from a Remote Host
The Serial Communications module exchanges commands with the remote host via the input and output memory areas of the I/O Station’s Genius NIU. The commands used for these communications are referred to as "memory mapped COMMREQs" because their format is similar to the existing GE Fanuc Modbus RTU COMMREQ (Communication Request) commands. These commands are defined in the document Modbus RTU Communications, GFK-2220C or later, which is available at http://globalcare.gefanuc.com, and on the Infolink for PLC CD set.

Commands from the remote host to the module are sent via %AQ memory. The module returns the command response in the first two %AI registers that have been configured for the module.

The Serial Communications module supports RTU Master command numbers 65520, 8000, 8001, 8002, and 8003 as described in the Modbus RTU Communications Manual, GFK-2220.

Compatibility: The Modbus Serial Master module is compatible with the VersaMax Genius NIU (IC200GBI001) only, no other VersaMax NIUs or VersaMax CPUs are supported at this time.

Flexibility: The Modbus Serial Master module is ideal for interfacing with a variety of third party Modbus Slave devices. The Genius NIU can easily be connected to any PAC or Series 90 controller.

Typical Applications

  • Water/Waste Water
    • Pumping stations
    • Lift stations
  • Transportation
    • Traffic control
    • Ventilation systems
  • Any application that has third party slave devices such as Variable Frequency Drives, marques, displays, controllers and other devices that communicate over Modbus serial.

Customer CTQs
  • Remote interface to Modbus Serial devices over a Genius LAN
  • Simple interface support to PAC controllers
  • Support redundant LANs
Specifications
Serial Modbus Master Module
Number of Serial Communications Modules Up to 2 per Genius NIU I/O Station
Number of RTU slaves per Serial Communications Module 1 to 247
Serial Port Type

RS-485. 15-pin subminiature ‘D’ connector.
For RS-232 communications, an RS-485 to RS-232 adapter such as IC690ACC901 can be used. Adapter IC690ACC901 can be installed with its right-angle cable hanging down.
RS-485 supports both 2-wire and 4-wire electrical interfaces

Baud Rate Supported 1200, 2400, 4800, 9600, and 19200, and half or full duplex operation
COMMREQ command memory (%AQ) required in the GENERIC_COMM module hardware configuration Depends on individual COMMREQ content.
Minimum: 22 words
Maximum: 64 words
COMMREQ response memory (%AI) required Minimum: 2 words
Maximum: 64 words for Genius NIU
RTU Master Commands

As described in Modbus RTU Communications Manual, GFK-2220. Minor differences as described below.
65520, Initialize RTU Master Port
8000, Clear RTU Master Dig. Status
8001, Read RTU Master Dig. Status
8002, Send RTU Read/Force/Preset Query
8003, Send RTU Diagnostic Query


VersaMax Micro 64 Ordering Information
Part number
Description Open for orders
IC200CMM020 VersaMax Modbus Master Serial Communications Module NOW

Firmware and Software Requirements
No new firmware required on Genius NIU or CPU.

Related Documentation
Documentation is located at http://globalcare.gefanuc.com.

GFK Description
GFK-2423 VersaMax Serial Communications ModuleVersaMax Micro 64 Data Sheet